Reference  
TVS600 & TVS600A Series  
Waveform Analyzers  
070-9918-00  
This document supports firmware version 1.5 and  
above.  
 
Quick Reference to  
TVS600 & TVS600A Commands  
This manual provides an abbreviated reference to the commands of  
TVS600 and TVS600A Series Waveform Analyzers. Use this  
reference to find the correct syntax for the commands. The  
commands are grouped by subsystem node and listed in alphabetical  
order.  
In general, the term TVS600A includes the TVS600A and the  
TVS600 models. Some commands apply only to TVS600A models;  
these commands appear in bold type.  
Syntax  
Commands ending with “?” are queries only. Commands ending with  
“[?]” have command and query forms. All other commands do not  
have a query form. Items in brackets [] are optional.  
Commands include the argument type for their command form, and  
their query form when applicable. The types are briefly defined as  
follows:  
<bin–block> — binary data block  
<boolean> — ON or 1, OFF or 0  
<expression> — algebraic expression  
<hex> — hexadecimal number: #HFF  
<none> — no command argument  
<NRf> — flexible number format: NR1, NR2 or NR3  
<string> — quoted ASCII character string  
TVS600 & TVS600A Series Waveform Analyzers Reference  
1
 
Quick Reference to TVS600 & TVS600A Commands  
Commands can also include the argument-type enumerated; for this  
type, the alternative argument forms are listed as follows:  
Form:  
Example:  
<arg1 | arg2 | argn> <BPASs | HPASs | LPASs |  
NOTCh>  
<arg1–argn>  
<CHAN1–CHAN4>  
Sometimes the forms are combined, for example:  
<CHAN1–CHAN4 | AATS | CALC1–CALC4>  
which means:  
(one of CHAN 1, CHAN 2 , CHAN 3, or CHAN 4) OR  
AATS OR (one of CALC1, CALC2, CALC3, or CALC4)  
For detailed descriptions of the commands and argument types, refer  
to your TVS600 & TVS600A Series Command Reference manual.  
TVS600 & TVS600A Series Waveform Analyzers Reference  
2
 
Quick Reference to TVS600 & TVS600A Commands  
Commands  
Some commands in the following list apply only to TVS600A  
models; these commands appear in bold type.  
AADVance  
Commands in the [SENSe:]AADVance subsystem control how  
auto-advance acquisition records are acquired and transferred to a  
VXIbus controller.  
AADVance  
[:STATe][?] <boolean>  
:COUNt[?] <NRf>  
:RECord  
:COUNt[?] <NRf>  
:STARt[?] <NRf>  
ABORT  
This command in the ABORt subsystem operates in combination  
with the ARM and TRIGger subsystems to stop signal acquisition.  
ABORt <none>  
ARM  
Commands in the ARM subsystem operate in combination with the  
TRIGger, INITiate, and ABORt subsystems to trigger acquisitions.  
ARM[:A]  
:DEFine?  
[:LAYer[1]]  
:SOURce[?] <BUS | ECLTrg0-1 | IECLTrg0–1 | ITTLTrg0-7  
| IMMediate | TTLTrg0-7>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
3
 
Quick Reference to TVS600 & TVS600A Commands  
AVERage  
Commands in the [SENSe:]AVERage subsystem control  
averaging (on incoming waveforms) in the SENSe block, which  
occurs prior to processing of the waveforms by the CALCulate  
block.  
AVERage  
[:STATe][?] <boolean>  
:COUNt[?] <NRf>  
:TYPE[?] <ENVelope | SCALar | PEAKdetect>  
CALCulage <n>  
Commands in the CALCulate subsystem process and perform  
measurements on acquisition records. These calculations are  
typically performed immediately after the waveform analyzer  
completes acquisition of the source. You can use CALCulate:IM-  
Mediate to reprocess and measure an existing acquisition record.  
CALCulate<n>  
:AAMList[?] <see page 22>  
:STATe[?] <boolean>  
:DATA? <none>  
:PREamble? <none>  
:DERivative  
:STATe[?] <boolean>  
:FEED[1][?] <string | CHAN1–CHAN4 | REF1–REF10>  
:FEED2[?] <string | CHAN1–CHAN4 | REF1–REF10>  
:CONTEXT  
:FILTer  
:FREQuency  
[:TYPE][?] <BPASs | HPASs | LPASs | NOTCh>  
:CENTer[?] <NRf>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
4
 
Quick Reference to TVS600 & TVS600A Commands  
:HPASs[?] <NRf>  
:LPASs[?] <NRf>  
:SPAN[?] <NRf>  
:SREJection[?] <NRf>  
:STARt[?] <NRf>  
:STATe[?] <boolean>  
:STOP[?] <NRf>  
:TWIDth[?] <NRf>  
:FORMat[?] <COMPlex | MLINear | MLOGarithmic | NONE  
| PHASe | POLar>  
:IMMediate[?] <none>  
:INTegral  
:STATe[?] <boolean>  
:PATH[?] <AAMList | DERivative | FILTer | FORMat | INTegral  
| SMOothing | TRANsform1 | WMList>  
:EXPRession[?] <expression>  
:SMOothing  
[:STATe][?] <boolean>  
:POINts[?] <NRf>  
:TRANsform  
:FREQuency  
:STATe[?] <boolean>  
:WINDow[?] <BHARris | BLACkman | HAMMing  
| HANNing | RECTangular | TRIangular>  
:WMList[?] <See page 22>  
:STATe[?] <boolean>  
:WMParameter  
TVS600 & TVS600A Series Waveform Analyzers Reference  
5
 
Quick Reference to TVS600 & TVS600A Commands  
:EDGE[?] <NRf>  
:GATE[?] <boolean>  
:METHod[?] ABSolute | RELative  
:STARt  
[:ABSolute][?] <NRf>  
:RELative[?] <NRf>  
:STOP  
[:ABSolute][?] <NRf>  
:RELative[?] <NRf>  
:HIGH[?] <NRf>  
:HMEThod[?] <ABSolute | AUTO | MODE | PEAK>  
:LOW[?] <NRf>  
:LMEThod[?] <ABSolute | AUTO | MODE | PEAK>  
:HREFerence  
[:ABSolute][?] <NRf>  
:RELative[?] <NRf>  
:LREFerence  
[:ABSolute][?] <NRf>  
:RELative[?] <NRf>  
:MREFerence  
[:ABSolute][?] <NRf>  
:HYSTeresis[?] <NRf>  
:RELative[?] <NRf>  
:RMEThod[?] <ABSolute | RELative>  
:SLOPe[?] <NRf>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
6
 
Quick Reference to TVS600 & TVS600A Commands  
CALibration  
Commands in the CALibration subsystem run the waveform analyzer  
self-calibration functions.  
CALibration  
[:ALL][?] <none>  
:RESults  
[:CODE]? <none>  
:VERBose? <none>  
:PROBe[n][?] <none>  
:RESults?  
DATA?  
Commands in the [SENSe:]FUNCtion and [SENSe:]DATA  
subsystems control sense functions and provide a means of accessing  
the data produced by the sense functions.  
DATA? <string>  
:PREamble? <string>  
FORMat  
Commands in the FORMat subsystem set the format of acquisition  
record data and measurement data transferred out of the waveform  
analyzer. The primary data transfer commands are CALCu-  
late:DATA?, [SENse:]DATA?, and TRACe[:DATA]?.  
FORMat  
:BORDer[?] <NORMal | SWAPped>  
[:DATA][?] <ASCii,[0] | INTeger,[16]>  
:CALCulate<n>[?] <ASCii,[0] | INTeger,[16]>  
:TRACe  
:AATS[?] <ASCii,[0] | REAL,[32]>  
:REF[?] <ASCii,[0] | REAL,[32]>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
7
 
Quick Reference to TVS600 & TVS600A Commands  
:DINTerchange[?] <boolean>  
FUNCtion  
Commands in the [SENSe:]FUNCtion and [SENSe:]DATA  
subsystems control sense functions and provide a means of accessing  
the data produced by the sense functions.  
FUNCtion  
[:ON][?] <string | CHAN1–CHAN4>  
:ALL <none>  
:COUNt? <none>  
:OFF[?] <string | CHAN1–CHAN4>  
:ALL <none>  
:COUNt? <none>  
:CONCurrent[?] <boolean>  
:STATe? <string>, <boolean>  
INITiate  
Commands in the INITiate subsystem operate in combination with  
the ARM and TRIGger subsystems to start signal acquisition.  
INITiate  
[:IMMediate] <none>  
:CONTinuous[?] <boolean>  
:COUNt[?] <NRf>  
INPut<n>  
Commands in the INPut subsystem control input coupling,  
bandwidth limiting, input impedance, and so on. The input channel  
number, defined at the probe connector, is shared as the parameter  
<n> for the INPut<n> and VOLTage<n> commands.  
INPut<n>  
:COUPling[?] <AC | DC | GROund>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
8
 
Quick Reference to TVS600 & TVS600A Commands  
:FILTer  
[:LPASs]  
[:STATe][?] <boolean>  
:FREQuency[?] <NRf>  
:IMPedance[?] <NRf>  
:PROBe  
:ATTenuation?  
:IDENtification?  
:OFFSet?  
:PROTection  
:STATe[?] <boolean>  
MEMory  
Commands in the MEMory subsystem store and retrieve instrument  
settings. The waveform analyzer can store the current instrument  
state in any of ten nonvolatile memory locations or in a file on your  
controller.  
MEMory  
:DATA[?] <SAV0–SAV10>  
:NSTates? <none>  
:STATe  
:CATalog? <none>  
:DEFine? <SAV0–SAV10>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
9
 
Quick Reference to TVS600 & TVS600A Commands  
OUTPut  
Commands in the OUTPut subsystem route signals to the VXIbus  
trigger lines and enable the probe compensation signals and  
reference signals.  
OUTPut  
:ECLTrg<n>  
[:STATE][?] <boolean>  
:POLarity[?] <NORMal | INVerted>  
:SOURce[?] <ARMed | ATRigger | BTRigger | CALC  
| OPC>  
:PCOMpensate  
[:STATE][?] <boolean>  
FUNCtion[?] <CLOCk | VOLTage>  
:REFerence  
[:STATE][?] <boolean>  
:FUNCtion[?] <CLOCk | VOLTage>  
:TTLTrg<n>  
[:STATE][?] <boolean>  
:POLarity[?] <NORMal | INVerted>  
:SOURce[?] <ARMed | ATRigger | BTRigger | CALC  
| OPC>  
ROSCillator  
Commands in the SENSe:ROSCillator subsystem control the source  
of the reference oscillator (clock) for the :SWEep subsystem.  
ROSCillator  
:SOURce[?] <CLK10 | INTernal>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
10  
 
Quick Reference to TVS600 & TVS600A Commands  
[SENSe:]  
Commands in the [SENse:] system appear in the references that  
follow:  
[SENSe:]  
see AADVance  
see AVERage  
see DATA  
see FUNCtion  
see ROSCillator  
see SWEep  
see VOLTage  
STATus  
Commands in the STATus subsystem can determine the state of the  
waveform analyzer and control what events can interrupt the system  
controller. For an overview of the status and event reporting system,  
refer to your user manual.  
STATus  
:OPERation  
[:EVENt]? <none>  
:CONDition? <none>  
:ENABle[?] <NRf>|<hex>  
:NTRansition[?] <NRf>|<hex>  
:PTRansition[?] <NRf>|<hex>  
:QENable  
:NTRansition[?] <NRf>|<hex>  
:PTRansition[?] <NRf>|<hex>  
:PRESet <none>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
11  
 
Quick Reference to TVS600 & TVS600A Commands  
:QUEStionable  
[:EVENt]? <none>  
:CONDition? <none>  
:ENABle[?] <NRf>|<hex>  
:NTRansition[?] <NRf>|<hex>  
:PTRansition[?] <NRf>|<hex>  
:QENable  
:NTRansition[?] <NRf>|<hex>  
:PTRansition[?] <NRf>|<hex>  
:SESR  
:QENable[?] <NRf>|<hex>  
SWEep  
Commands in the [SENSe:]SWEep subsystem control the acquisition  
time base for all VOLTage[n] acquisitions.  
SWEep  
:OFFSet  
:POINts[?] <NRf>  
:TIME[?] <NRf>  
:OREFerence  
:LOCation[?] <NRf>  
:POINts[?] <NRf>  
:TIME[?] <NRf>  
:TINTerval[?] <NRf>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
12  
 
Quick Reference to TVS600 & TVS600A Commands  
SYSTem  
Commands in the SYSTem subsystem program utility functions and  
return version information about the waveform analyzer.  
SYSTem  
:AUToset  
:VOLTage <CHAN1–CHAN4>  
:SWEep <CHAN1–CHAN4>  
:TRIGger <CHAN1–CHAN4>  
:BDATe[?] <NRf>, <NRf>, <NRf>  
:CDATe[?] <NRf>, <NRf>, <NRf>  
:COMMunicate  
:SERial  
:BAUD[?] <NRf>  
:CONTrol  
:DCD[?] <boolean>  
:RTS[?] <OFF | ON | IBFull | RFR>  
:ECHO[?] <boolean>  
:ERESponse[?] <boolean>  
:LBUFfer[?] <boolean>  
:PACE[?] <NONE | XON>  
:PARity[?] <EVEN | NONE | ODD>  
:PRESet  
[:ALL] <none>  
:RAW <none>  
:TERMinal <none>  
:SBITs[?] <NRf>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
13  
 
Quick Reference to TVS600 & TVS600A Commands  
:ERRor  
[:NEXT]? <none>  
:ALL? <none>  
:CODE  
[:NEXT]? <none>  
:ALL? <none>  
:COUNt? <none>  
:PROTect[?] <boolean>  
:SECurity  
:IMMediate <none>  
:SET[?] <bin–block>  
:VERSion? <none>  
TEST  
Commands in the TEST subsystem execute the internal self-tests of  
the waveform analyzer module and return the pass or fail status.  
TEST  
[:ALL][?] <none>  
:RESults  
[:CODE]? <none>  
:VERBose? <none>  
:STOP  
TVS600 & TVS600A Series Waveform Analyzers Reference  
14  
 
Quick Reference to TVS600 & TVS600A Commands  
TRACe?  
Commands in the Trace subsystem transfer acquisition records or  
measurement results and their data preambles from the waveform  
analyzer to the VXIbus controller or to internal REF storage  
locations. (The data preamble includes scaling and length informa-  
tion for the associated data record.) See the FORMAT subsystem for  
setting the format for data transfers.  
The query does not return data until pending acquisitions or  
calculations complete. Hence, the synchronizing commands *WAI,  
*OPC, and *OPC? are not required.  
TRACe?  
[:DATA]?  
<CHAN1–CHAN4 | AATS | CALC1–CALC4 | REF1–REF10>  
:PREamble? <CHAN1–CHAN4 | AATS | CALC1–CALC4  
| REF1–REF10>  
:DELete  
[:NAME] <REF1–REF10>  
TRACe:DELete:ALL  
:CATalog? <none>  
:COPy <FDC1 | REF1–REF10>,CHAN1–CHAN4 | AATS  
| CALC1–CALC4 | LIST | REF1–REF10>  
:FEED? <CHAN1–CHAN4 | REF1–REF10 | AATS  
| CALC1–CALC4>  
:LIST[?] <CHAN1–CHAN4 | REF1–REF10 | AATS  
| CALC1–CALC4 | NONE>  
:POINts? <CHAN1–CHAN4 | REF1–REF10 | AATS  
| CALC1–CALC4>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
15  
 
Quick Reference to TVS600 & TVS600A Commands  
TRIGger[:A]  
Commands in the TRIGger[:A] subsystem operate in combination  
with the ARM, INITiate, TRIGger:B and ABORt subsystems to  
trigger acquisitions. The defined alias for the SCPI trigger  
:SEQuence[1] is A.  
TRIGger  
[:A]  
:ATRigger  
[:STATe][?] <boolean>  
:COUPling[?]AC | DC  
:<preset>  
:DEFine? <none>  
:DELay[?] <NRf>  
:FILTer  
[:LPASs]  
[:LPASs]  
[:STATe][?] <boolean>  
:HPASs  
[:STATe][?] <boolean>  
:NREJect[?]  
[:STATe][?] <boolean>  
:HOLDoff  
:TIME[?] <NRf>  
:LEVel[?] <NRf>  
:METastable:STATe[?] <REJect | ACCept| AUTo>  
:SLOPe[?] <POSitive | NEGative>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
16  
 
Quick Reference to TVS600 & TVS600A Commands  
:SOURce[?] <ECLTrg0 | ECLTrg1 | EXTernal | IMMediate  
| INTernal1–INTernal4 | TTLTrg0–TTLTrg7>  
:TYPE[?]  
<EDGE | LOGic | PULSe | SHOLdtime | TRANsition>  
TRIGger[:A]:PULSe  
Commands in the TRIGger:PULSe subsystem provide the capability  
to trigger when a pulse occurs that is outside specified parameters.  
TRIGger  
[:A]  
:PULSe  
:CLASs[?] <GLITch | TIME | WIDTh>  
:GLITch  
:POLarity[?] <EITHer | NEGative | POSitive>  
:QUALify[?] <GT | LT>  
:WIDTh[?] <NRf>  
:SOURce[?] <INTernal1–INTernal4>  
:TIMEout  
:POLarity[?]<NEGative | POSitive>  
:WIDTh[?] <NRf>  
:THReshold[?] <NRf>  
:WIDTh  
:HLIMit[?] <NRf>  
:LLIMit[?] <NRf>  
:POLarity[?] <NEGative | POSitive>  
:QUALify[?] <IN | OUT>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
17  
 
Quick Reference to TVS600 & TVS600A Commands  
TRIGger[:A]:LOGic  
Commands in the TRIGger:LOGic subsystem provide the capability  
to trigger on logic patterns, clocked or not clocked. TVS600A  
models only.  
TRIGger  
[:A]  
:LOGic  
:CLASs[?] <PATTerm | STATe>  
:CONDition[?] <LCXXX0 | LCXXX1| .... | LC1111>  
:FUNCtion[?] <AND | NAND | NOR | OR>  
:PATTern  
:QUALify[?] <GT | LT | OFF>  
:WIDTh[?] <NRf>  
:STATe  
:SLOPe[?] <NEGative | POSitive>  
:THReshold[n][?] <NRf>  
TRIGger[:A]:SHOLdtime  
Commands in the TRIGger:SHOLdtime (setup and hold) subsystem  
provide the capability to monitor and trigger on data that violates a  
setup-and-hold time zone that you set. TVS600A models only.  
TRIGger  
[:A]  
:SHOLdtime  
:CLOCk  
:POLarity[?] <NEGative | POSitive>  
:SOURce[?] <INTernal1–INTernal4>  
:THReshold[?] <NRf | MAXimum | MINimum>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
18  
 
Quick Reference to TVS600 & TVS600A Commands  
:DATA  
:SOURce[?] <INTernal1–INTernal4>  
:THReshold[?] <NRf | MAXimum | MINimum>  
:HTIMe[?] <NRf | MAXimum | MINimum>  
:STIMe[?] <NRf | MAXimum | MINimum>  
TRIGger[:A]:TRANsition  
Commands in the TRIGger TRANsition subsystem provide the  
capability to trigger on runt pulses or to trigger based on the slew  
rate of a pulses edge. TVS600A models only.  
TRIGger  
[:A]  
:TRANsition  
:CLASs[?] <RUNT | SLEW>  
:RUNT  
:QUALify[?] <GT | OFF>  
:SLOPe[?] <EITHer | NEGative | POSitive>  
:SLEW  
:QUALify[?] <GT | LT>  
:SLOPe[?] <NEGative | POSitive>  
:SOURce[?] <INTernal1–INTernal4>  
:THReshold  
:HIGH[?] <NRf>  
:LOW[?] <NRf>  
:TIME[?} <NRf>  
TVS600 & TVS600A Series Waveform Analyzers Reference  
19  
 
Quick Reference to TVS600 & TVS600A Commands  
TRIGger:B  
Commands in the TRIGger:B subsystem operate in combination with  
the ARM, INITiate, TRIGger[:A] and ABORt subsystems to trigger  
acquisitions. The TRIGger:B subsystem is an alias for the SCPI  
SEQuence2 trigger block. The defined alias for the SCPI trigger  
:SEQuence[2] is :B.  
TRIGger  
:B  
:COUPling[?] <AC | DC>  
:<preset>  
:DELay[?] <NRf>  
:ECOunt[?] <NRf>  
:FILTer  
[:LPASs]  
[:STATe][?] <boolean>  
:HPASs  
[:STATe][?] <boolean>  
:NREJect[?]  
[:STATe][?] <boolean>  
:LEVel[?] <NRf>  
:SEQuence2  
:DEFine? <none>  
:SLOPe[?] <NEGative | POSitive>  
:SOURce[?] <EXTernal | IMMediate | INTernal1  
–INTernal4>.  
TVS600 & TVS600A Series Waveform Analyzers Reference  
20  
 
Quick Reference to TVS600 & TVS600A Commands  
VOLTage>n>  
This command ([SENSe:]VOLTage subsystem) sets the vertical  
window size for input channel specified by <n>. The input channel  
number, defined at the probe connector, is shared as the parameter  
<n> for the INPut<n> and VOLTage<n> commands.  
VOLTage<n>  
[:DC]  
:RANGe  
[:UPPer][?] <NRf>  
:LOWer[?] <NRf>  
:OFFSet[?] <NRf>  
:PTPeak[?] <NRf>  
IEEE 488.2 Common Commands  
The program mnemonics are described in alphabetical order below.  
*CAL?  
*LRN?  
*RST  
*SRE[?]  
*TRG  
*TST?  
*WAI?  
*CLS  
*OPC[?] *SAV  
*ESE[?] *OPT?  
*ESR?  
*IDN?  
*PUD[?] *STB?  
*RCL  
TVS600 & TVS600A Series Waveform Analyzers Reference  
21  
 
Quick Reference to TVS600 & TVS600A Commands  
AAMList and WMList Parameters  
The table that follows lists the measurements available as arguments  
to the CALCulate<n>:AAMList[?] and :WMList[?] (see pages 4 and 5,  
respectively.  
<list>  
AMPLitude  
AREA  
MINimum  
NCRoss  
CARea  
CMEan  
COPulse  
NDUTycycle  
NWIDth  
1
1
OVERshoot  
1
1
CPARea  
PARea  
CRMS  
CROSs  
DELay  
PCRoss  
PERiod  
PDUTycycle  
PHAse  
FREQuency  
1
FTIMe  
GAIN  
HIGH  
PREShoot  
PTPeak  
PWIDth  
RMS | AC  
RTIMe  
SDEViation  
TTRig  
LOW  
MAXimum  
MEAN | DC  
MID  
1
TVS600A only  
TVS600 & TVS600A Series Waveform Analyzers Reference  
22  
 

Tascam Guitar GB 10 User Manual
TDK Network Card EE320x250x20 User Manual
Technicolor Thomson Stereo System CS1200VD User Manual
Toshiba Printer TF 610 User Manual
TRENDnet Network Router TEW 430APB c1 User Manual
Tripp Lite Universal Remote URM 15T User Manual
ViewSonic Computer Monitor G75F+ User Manual
Weber Cooktop S 460 User Manual
Weed Eater Lawn Mower 186843 User Manual
Weed Eater Lawn Mower 438181 User Manual