Ultra Products Power Supply ULT33062 User Manual

Uninterrupted  
Power Supply (UPS)  
The Ultimate Power Protection!  
If you're looking for the most complete, technologically advanced power protection  
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an  
absolute must for anyone running a small server, workstation or a powerful PC. We're  
so confident that our UPS will offer you ultimate power protection, it carries a  
$125,000 guarantee against damage to any equipment connected to the UPS. You  
simply cannot afford to cut corners when it comes to safeguarding your valuable  
equipment, and these UPS's deliver the comprehensive protection for computer,  
peripherals and data files at a remarkably low price.  
Includes  
Features  
UPS Monitoring  
- AVR (Automatic Voltage Regulation)  
- Fully Digitized Microprocessor Controlled  
- Protects up to 4 Devices at Once  
- Energy Saving Function (UPS Green Mode)  
- 50/60Hz Frequency Auto Sensing and Selection  
- USB Communication Port  
Software  
- Advanced Battery Management (ABM Technology)  
300VA  
500VA  
700VA  
850VA  
Gneral  
Output  
Sku  
ULT33061  
ULT33062  
ULT33063  
ULT33064  
Backup Time  
4-6 minutes (a PC with 15” CRT monitor)  
8-12 minutes (a PC with 15” LCD monitor)  
1.9(4.2)  
No  
150  
300VA  
Style A UPSx3, Bypassx3  
Simulated sine wave at 120V +/- 5%  
50 or 60Hz +/- 0.3Hz  
2-4 milliseconds, including detection time  
120V +15%/-20% at line input  
50 or 60Hz +/- 10% (auto sensing)  
Circuit breaker for overload & short circuit protection  
AC Mode: If load exceeds 110% of nominal, Buzzer  
beeps continuously.  
7-9 minutes (a PC with 15” CRT monitor)  
14-16 minutes (a PC with 15” LCD monitor)  
2.58(5.67)  
No  
250  
500VA  
Style A UPSx3, Bypassx3  
Simulated sine wave at 120V +/- 5%  
50 or 60Hz +/- 0.3Hz  
2-4 milliseconds, including detection time  
120V +15%/-20% at line input  
50 or 60Hz +/- 10% (auto sensing)  
Circuit breaker for overload & short circuit protection  
AC Mode: If load exceeds 110% of nominal, Buzzer  
9-11 minutes (a PC with 15” CRT monitor)  
17-19 minutes (a PC with 15” LCD monitor)  
2.58(5.67)  
No  
350  
700VA  
Style A UPSx3, Bypassx3  
Simulated sine wave at 120V +/- 5%  
50 or 60Hz +/- 0.3Hz  
2-4 milliseconds, including detection time  
120V +15%/-20% at line input  
50 or 60Hz +/- 10% (auto sensing)  
Circuit breaker for overload & short circuit protection  
AC Mode: If load exceeds 110% of nominal, Buzzer  
16-20 minutes (a PC with 15” CRT monitor)  
36-40 minutes (a PC with 15” LCD monitor)  
4.1(9.1)  
No  
425  
850VA  
Style A UPSx4, Bypassx4  
Simulated sine wave at 120V +/- 5%  
50 or 60Hz +/- 0.3Hz  
2-4 milliseconds, including detection time  
120V +15%/-20% at line input  
50 or 60Hz +/- 10% (auto sensing)  
Circuit breaker for overload & short circuit protection  
AC Mode: If load exceeds 110% of nominal, Buzzer  
Net Weight Kg (lbs)  
Digital Display  
Watts  
UPS Capacity  
No. of Sockets  
Voltage (Battery)  
Frequency (Battery)  
Transfer Time  
Voltage (Single Phase)  
Frequency  
Input  
Protection  
Unit Input  
Overload Protection  
beeps continuously. If load exceeds 120% of nominal for beeps continuously. If load exceeds 120% of nominal for beeps continuously. If load exceeds 120% of nominal for  
Backup Mode: If load exceeds 110% of nominal for 1  
second, UPS shuts down automatically.  
30 seconds, 130% for 3 seconds, UPS shuts down  
automatically.  
30 seconds, 130% for 3 seconds, UPS shuts down  
automatically.  
30 seconds, 130% for 3 seconds, UPS shuts down  
automatically.  
Back up Mode: If load exceeds 105% of nominal for 20 Back up Mode: If load exceeds 105% of nominal for 20 Back up Mode: If load exceeds 105% of nominal for 20  
seconds, 120% for 10 seconds, 130% for 3 seconds,  
UPS shuts down automatically.  
UPS output shuts off immediately  
1140 Joules, 2ms  
Sealed, maintenance-free lead acid battery, with 3-6  
years typical lifetime  
6 hours (to 90% of full capacity)  
seconds, 120% for 10 seconds, 130% for 3 seconds,  
UPS shuts down automatically.  
UPS output shuts off immediately  
1140 Joules, 2ms  
Sealed, maintenance-free lead acid battery, with 3-6  
years typical lifetime  
6 hours (to 90% of full capacity)  
seconds, 120% for 10 seconds, 130% for 3 seconds,  
UPS shuts down automatically.  
UPS output shuts off immediately  
1520 Joules, 2ms  
Sealed, maintenance-free lead acid battery, with 3-6  
years typical lifetime  
6 hours (to 90% of full capacity)  
Short Circuit  
Surge Protection  
Type  
UPS output shuts off immediately  
1140 Joules, 2ms  
Sealed, maintenance-free lead acid battery, with 3-6  
years typical lifetime  
Battery  
Typical Recharge Time 4 hours (to 90% of full capacity)  
Protection  
Automatic self-test, Over discharge protection, short  
circuit protection by fuse  
Automatic self-test, Over discharge protection, short  
circuit protection by fuse  
Automatic self-test, Over discharge protection, short  
circuit protection by fuse  
Automatic self-test, Over discharge protection, short  
circuit protection by fuse  
Interface  
Alarm  
USB  
Battery low detecting, UPS on/off scheduling AC  
input/output power status display.  
Slow beeping sound every 4 seconds  
Rapid beeping sound every second  
AC Mode: Rapid beeping sound every 0.5 second  
Continuous beeping sound  
Battery low detecting, UPS on/off scheduling AC  
input/output power status display.  
Slow beeping sound every 4 seconds  
Rapid beeping sound every second  
AC Mode: Rapid beeping sound every 0.5 second  
Continuous beeping sound  
Battery low detecting, UPS on/off scheduling AC  
input/output power status display.  
Slow beeping sound every 4 seconds  
Rapid beeping sound every second  
AC Mode: Rapid beeping sound every 0.5 second  
Continuous beeping sound  
Battery low detecting, UPS on/off scheduling AC  
input/output power status display.  
Slow beeping sound every 4 seconds  
Rapid beeping sound every second  
AC Mode: Rapid beeping sound every 0.5 second  
Continuous beeping sound  
Battery Backup  
Battery Low  
Abnormal Charge  
Overload  
Environment Ambient Operation  
3,500 meters max. elevation, 0-95% humidity non-  
condensing, 0-40?  
<40dBA (1 meter from surface)  
3,500 meters max. elevation, 0-95% humidity non-  
condensing, 0-40?  
<40dBA (1 meter from surface)  
3,500 meters max. elevation, 0-95% humidity non-  
condensing, 0-40?  
<40dBA (1 meter from surface)  
3,500 meters max. elevation, 0-95% humidity non-  
condensing, 0-40?  
<40dBA (1 meter from surface)  
Audible Noise  
1-800-830-0051  
 

Tech Craft TV Video Accessories PAL62 User Manual
Telex Headphones HD 3A User Manual
TOA Electronics Portable Speaker SR A12L User Manual
Tunturi Elliptical Trainer E5R User Manual
Tyco Battery Charger 92136 0920 User Manual
Uniden Printer 3315 User Manual
Uniden Telephone EXP 9100 User Manual
VDO Dayton Car Video System DV 6100 User Manual
Vivitar Camera Accessories MagnaCam 1025x1 Digital Camera Binocular User Manual
Vivotek Security Camera IP2112 User Manual