TRENDnet Welding System 1000 Base SX LX User Manual

Quick Installation Guide  
1000Base-SX/LX  
Fiber Converters  
 
1. Before You Start  
Package Contents  
Fiber Converter  
Quick Installation Guide  
AC Power Supply (7.5 DC, 1.5A)  
System Requirements  
An environment that is free from strong electromagnetic field generators  
(such as motors), vibration, dust and direct exposure to sunlight  
TFC-1600 chassis (optional) or sturdy, level surface that can support the  
weight of the Fiber Converter  
10/100Mbps Ethernet Switch  
Multi-mode or Single-mode Fiber cables  
CAT-5 or CAT-6 RJ-45 Ethernet Cable  
Product Detail  
Multi/Single-Mode  
Model Name  
TFC-1000MSC  
TFC-1000S20  
Fiber Connector  
Multi-Mode  
SC (Duplex)  
Single-Mode  
TFC-1000S50  
TFC-1000S70  
TFC-1000S10D3  
TFC-1000S10D5  
Single-Mode  
Bidirectional  
SC (Simplex)  
1
 
English  
2. Hardware Installation  
Installing two stand alone Fiber Converters  
1. Connect the fiber cable to the fiber  
converters. This cable must be  
multi-mode for the TFC-1000MSC.  
This cable must be single-mode for  
the TFC-1000S20/S50/S70/S10D3/  
S10D5.  
2. Connect an RJ-45 Ethernet cable  
from the Ethernet port on the fiber  
converters to an Ethernet port on  
your switch (e.g TEG-S160TX or  
TEG-S240TX).  
3. Connect the power adapter to the  
back of the fiber converter.  
Note: The TX and RX cables must be reverse on the opposite fiber connection.  
Note: The TFC-1000S10D3 must be paired with the TFC-1000S10D5.  
2
 
English  
Installing Media Converter in a Chassis  
4. Unscrew the bay cover from the  
desired bay on the chassis.  
5. Unfasten the thumbscrew and  
remove the fiber converter from the  
metal casing.  
6. Slide the media converter into an  
available slot and fasten the  
thumbscrew.  
Your installation is now complete.  
3
 
English  
Specifications  
IEEE802.3ab 1000BASE-TX  
IEEE802.3z 1000BASE-SX/LX  
Applicable Standards:  
1 TX port, 1 FX port  
1488000pps for 1000Mbps  
PWR, LNK/ACT  
Fixed Ports:  
Forwarding rate:  
LED Indicators:  
Switch 1: On(Forced Mode); Off(Auto-Negotiation)  
Switch 2: On(LLR enabled); Off(LLR disabled)  
DIP Switches:  
1000BASE-T  
Cat. 5e or Cat. 6 EIA/TIA-568 100-ohm screened  
twisted-pair (STP)  
1000BASE-SX  
62.5/125µm multi-mode fiber optic cable  
50/125µm multi-mode fiber optic cable  
Cable :  
1000BASE-LX  
9/125µm single-mode fiber optic cable  
10/125 µm single-mode fiber optic cable  
Dimensions:  
Weight:  
L120 × W88 × H25 mm  
305 g  
External power adaptor 7.5V 1.5A  
5.5 Watts Max.  
Power:  
Power Consumption:  
Operating: 0°C ~ 40°C (32°F ~ 104°F)  
Storage: -25°C ~ 70°C (-13°F ~ 158°F)  
Temperature:  
Humidity:  
10 ~ 90%, non-condensing  
FCC part 15 Class B, CISPR ClassB, VCCI Class B,  
CE Mark  
Certifications:  
4
 
Ordering Information  
Media Converters  
Port 1  
Port 2  
Cable(/125 µm )  
/Connector  
Model Number  
TFC-1000MSC  
TFC-1000S20  
TFC-1000S50  
TFC-1000S70  
TFC-1000S10D3  
TFC-1000S10D5  
Speed  
(Mbps)  
Speed  
(Mbps)  
Max.  
Distance  
Max.  
Distance  
Wavelength  
Cable/Connector  
220M  
62.5/125µm  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
MMF  
(50µm or 62.5µm )  
MT-RJ  
1000  
1000  
1000  
1000  
1000  
1000  
100M  
100M  
100M  
100M  
100M  
100M  
1000  
1000  
1000  
1000  
1000  
1000  
1300nm  
550M  
50/125µm  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
MMF  
(50µm or 62.5µm ) 20 km  
SC  
1300nm  
1300nm  
1300nm  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
MMF  
(50µm or 62.5µm ) 50 km  
ST  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
SMF  
(9µm or 10µm )  
SC  
70 km  
20 km  
20 km  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
Bi-directional SMF  
(9µm or 10µm )  
SC  
TX: 1310nm  
RX: 1550nm  
Cat. 3, 4, 5,  
EIA/TIA-568  
100-ohm STP  
Bi-directional SMF  
(9µm or 10µm )  
SC  
TX: 1310nm  
RX: 1550nm  
Note: MMF (multi-mode fiber); SMF (single-mode fiber)  
5
 
Troubleshooting  
Q1: After connecting the Fiber converter, the LEDs do not turn on. What should I  
do?  
A1: First, check that the power outlet is receiving power. Second, make sure the  
power adapter is firmly connected to the Fiber converter and the power outlet.  
Third, make sure the Ethernet and the Fiber cables are connected.  
Q2: All the LEDs are on, but I can't make a connection. What should I do?  
A2: First, verify that you are using the proper fiber cable (e.g. multi-mode fiber  
cable for multi-mode converter; single-mode fiber cables for single-mode  
converters). Second, verify that the TX and RX cables have been reverse on the  
opposite Fiber connection. Third, power down the fiber converters and the  
switches. Wait 15 seconds, then plug the switches and the fiber converters back  
in.  
Q3: What is the maximum distance that is supported by the fiber converter?  
A3: Please reference section 4 for distance information.  
If you still encounter problems or have any questions regarding the Fiber Converters  
please contact TRENDnet's Technical Support Department.  
6
 
Limited Warranty  
TRENDnet warrants its products against defects in material and workmanship, under  
normal use and service, for the following lengths of time from the date of purchase.  
Fiber Converters - 5 Year Warranty  
If a product does not operate as warranted above during the applicable warranty period,  
TRENDnet shall, at its option and expense, repair the defective product or deliver to  
customer an equivalent product to replace the defective item. All products that are  
replaced will become the property of TRENDnet. Replacement products may be new or  
reconditioned.  
TRENDnet shall not be responsible for any software, firmware, information, or memory  
data of customer contained in, stored on, or integrated with any products returned to  
TRENDnet pursuant to any warranty.  
There are no user serviceable parts inside the product. Do not remove or attempt to  
service the product through any unauthorized service center. This warranty is voided if  
(i) the product has been modified or repaired by any unauthorized service center, (ii) the  
product was subject to accident, abuse, or improper use (iii) the product was subject to  
conditions more severe than those specified in the manual.  
Warranty service may be obtained by contacting TRENDnet office within the applicable  
warranty period for a Return Material Authorization (RMA) number, accompanied by a  
copy of the dated proof of the purchase. Products returned to TRENDnet must be pre-  
authorized by TRENDnet with RMA number marked on the outside of the package, and  
sent prepaid, insured and packaged appropriately for safe shipment.  
7
 
WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE  
AS WARRANTED ABOVE, THE CUSTOMER’S SOLE REMEDY SHALL BE, AT  
TRENDNET’S OPTION, REPAIR OR REPLACEMENT. THE FOREGOING  
WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESSED OR IMPLIED, EITHER IN FACT OR BY OPERATION OF  
LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TRENDNET  
NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT  
ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION,  
MAINTENANCE OR USE OF TRENDNET’S PRODUCTS.  
TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND  
EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES  
NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S  
MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED  
ATTEMPTS TO REPAIR OR MODIFY, OR ANY OTHER CAUSE BEYOND THE  
RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER  
HAZARD.  
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW TRENDNET  
ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER  
BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL,  
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND,  
OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF  
INFORMATION OR DATE, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN  
CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE,  
PERFORMANCE, FAILURE, OR INTERRUPTION OF THE POSSIBILITY OF SUCH  
DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND  
OF THE PURCHASE PRICE PAID, AT TRENDNET’S OPTION. THIS DISCLAIMER OF  
LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED  
HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.  
Governing Law: This Limited Warranty shall be governed by the laws of the state of  
California.  
Note: AC/DC Power Adapter, Cooling Fan, Cables and Power Supply carry 1-Year  
Warranty  
8
 
Certifications  
This equipment has been tested and found to comply with FCC and CE Rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference.  
(2) This device must accept any interference received. Including interference that may  
cause undesired operation.  
Waste electrical and electronic products must not  
be disposed of with household waste. Please  
recycle where facilities exist. Check with you Local  
Authority or Retailer for recycling advice.  
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV  
INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS  
EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO  
OPERATE THE EQUIPMENT.  
ADVERTENCIA  
En todos nuestros equipos se mencionan claramente las caracteristicas del adaptador de  
alimentacón necesario para su funcionamiento. El uso de un adaptador distinto al  
mencionado puede producir daños fisicos y/o daños al equipo conectado. El adaptador  
de alimentación debe operar con voltaje y frecuencia de la energia electrica domiciliaria  
existente en el pais o zona de instalación.  
 
TRENDnet Technical Support  
.
US Canada  
Toll Free Telephone: 1(866) 845-3673  
24/7 Tech Support  
.
.
.
.
.
Europe (Germany France Italy Spain Switzerland UK)  
Toll Free Telephone: +00800 60 76 76 67  
English/Espanol - 24/7  
Francais/Deutsch - 11am-8pm, Monday - Friday MET  
Worldwide  
Telephone: +(31) (0) 20 504 05 35  
English/Espanol - 24/7  
Francais/Deutsch - 11am-8pm, Monday - Friday MET  
Product Warranty Registration  
Please take a moment to register your product online.  
20675 Manhattan Place  
Torrance, CA 90501  
USA  
 
Copyright ©2006. All Rights Reserved. TRENDnet.  

Targus Mouse AMB04 User Manual
Toshiba Laptop U845t User Manual
Toshiba Projector TDP PX10U User Manual
TP Link Telephone TL SF1005D User Manual
Trane Thermostat VariTrac Changeover Bypass VAV Systems User Manual
Tripp Lite Network Cables N024 01K User Manual
Vermont Casting Indoor Fireplace 2547CE User Manual
Victor Calculator 1240 3A User Manual
VXI Headphones USB 100 User Manual
Wagner SprayTech Paint Sprayer 555000 User Manual